MTS Device API - Endpoint Testing Results

Test Date: December 17, 2025
Gateway: MTCAP3 at 172.16.33.111
Firmware: 7.4.0-BETA2
API Version: 7.2.0
Test User: admin


Executive Summary

Tested 17 newly discovered PUT endpoints to verify configuration update functionality.

Results Overview

Status Count Percentage
Passed 13 76%
Failed 4 24%
⏭️ Skipped 0 0%

Overall Success Rate: 76%


Test Methodology

Test Procedure

For each endpoint:

  1. GET current configuration via /api?fields=<endpoint>
  2. PUT the same configuration back via /api/<endpoint>
  3. Verify response code and status
  4. Document any errors or limitations

Success Criteria


✅ Passed Tests (13 endpoints)

1. WAN Manager (/api/wanmngr)

2. Remote Access (/api/remoteAccess)

3. RADIUS (/api/radius)

4. SMTP (/api/smtp)

5. Auto Reboot (/api/autoReboot)

6. Reset Button (/api/resetButton)

7. Dynamic DNS (/api/ddns)

8. LLDP (/api/lldp)

9. mDNS (/api/mdns)

10. IP Passthrough (/api/ipPassthrough)

11. Cellular Time Sync (/api/cellTimeSync)

12. Remote Management (/api/remoteMgmt)

13. Custom Branding (/api/brand)


❌ Failed Tests (4 endpoints)

1. Bootloader (/api/bootloader)

2. SNTP (/api/sntp)

3. Back-off Timers (/api/backOffTimers)

4. Notification Event Group (/api/notificationEventGroup)


Detailed Findings

API Consistency Issues

  1. SNTP Endpoint
    • GET response missing required fields for PUT
    • Suggests schema validation mismatch
    • Recommendation: Align GET response with PUT requirements
  2. Notification Event Group
    • Path inconsistency between GET and PUT
    • GET: /api?fields=notificationEventGroup
    • PUT: /api/notificationEventGroup (returns 404)
    • Recommendation: Verify correct PUT path or implement endpoint

Read-Only Endpoints

Some endpoints appear to be read-only by design:

  1. backOffTimers - Carrier-specific defaults, not user-configurable
  2. bootloader - Hardware-dependent, may require special permissions

Successfully Tested Features

All major configuration categories work correctly:


Test Data Examples

Successful PUT Request Example (WAN Manager)

curl -k -X PUT https://172.16.33.111/api/wanmngr \
  -H "Content-Type: application/json" \
  -b cookies.txt \
  -d '{
    "mode": "FAILOVER",
    "wans": [
      {
        "interface": "eth0",
        "priority": 1,
        "weight": 1,
        "monitor": {
          "mode": "ACTIVE",
          "checkInterval": 60,
          "active": {
            "type": "ICMP",
            "hostname": "www.google.com",
            "icmpCount": 5
          }
        }
      }
    ]
  }'

Response:

{
  "code": 200,
  "status": "success"
}

Failed PUT Request Example (SNTP)

curl -k -X PUT https://172.16.33.111/api/sntp \
  -H "Content-Type: application/json" \
  -b cookies.txt \
  -d '{
    "enabled": true,
    "servers": ["time.google.com"]
  }'

Response:

{
  "code": 400,
  "status": "fail",
  "error": "[timeZones] property is not set"
}

Fix: Add missing timeZones property:

{
  "enabled": true,
  "servers": ["time.google.com"],
  "timeZones": "America/New_York"
}

Recommendations

For Documentation

  1. Update OpenAPI Spec
    • Mark bootloader and backOffTimers as read-only
    • Add note about sntp requiring timeZones field
    • Clarify notificationEventGroup PUT endpoint path
  2. Add Validation Notes
    • Document required vs optional fields for each endpoint
    • Include field validation rules (min/max, formats)
    • Provide error code reference
  3. Create Troubleshooting Guide
    • Common PUT operation errors
    • Field validation failures
    • Permission issues

For API Development

  1. Fix SNTP Endpoint
    • Include timeZones in GET response
    • Or make it optional in PUT request
    • Align schema between GET and PUT
  2. Clarify Read-Only Endpoints
    • Return 405 Method Not Allowed consistently
    • Include helpful error message
    • Document in API spec
  3. Path Consistency
    • Verify all PUT endpoint paths
    • Ensure GET query parameter maps to PUT path
    • Document any exceptions

For Testing

  1. Expand Test Coverage
    • Test with invalid data
    • Test field validation
    • Test partial updates
    • Test with different user roles
  2. Create Automated Tests
    • CI/CD integration
    • Regression testing
    • Schema validation

Next Steps

  1. ✅ Document test results (this document)
  2. ⏭️ Update OpenAPI spec with findings
  3. ⏭️ Test with different user roles (admin/user/guest)
  4. ⏭️ Create permission matrix
  5. ⏭️ File bug reports for failed endpoints
  6. ⏭️ Create workaround documentation

Appendix: Complete Test Results

Test Summary Table

# Endpoint Description Status Code Error
1 wanmngr WAN Manager Configuration ✅ PASSED 200 -
2 remoteAccess Remote Access Security ✅ PASSED 200 -
3 radius RADIUS Authentication ✅ PASSED 200 -
4 smtp SMTP Email Notifications ✅ PASSED 200 -
5 autoReboot Automatic Reboot Schedule ✅ PASSED 200 -
6 bootloader Bootloader Security ❌ FAILED 500 Factory error
7 resetButton Reset Button Configuration ✅ PASSED 200 -
8 sntp SNTP Time Sync ❌ FAILED 400 Missing timeZones
9 ddns Dynamic DNS ✅ PASSED 200 -
10 lldp Link Layer Discovery Protocol ✅ PASSED 200 -
11 mdns Multicast DNS ✅ PASSED 200 -
12 ipPassthrough IP Passthrough ✅ PASSED 200 -
13 backOffTimers Cellular Back-off Timers ❌ FAILED 405 Not allowed
14 cellTimeSync Cellular Time Sync ✅ PASSED 200 -
15 remoteMgmt Remote Management ✅ PASSED 200 -
16 brand Custom Branding ✅ PASSED 200 -
17 notificationEventGroup Notification Event Groups ❌ FAILED 404 Path not found

Test Environment


Report Generated: December 17, 2025
Tester: Automated Test Script
Review Status: Ready for documentation update